APC Smart-UPS VT 10kVA 208V with 1 Batt Mod Exp to 2, Int Maint Bypass, Parallel Capable SUVTP10KF1B2 APC Smart-UPS VT, 8000 Watts / 10 kVA,Input 208V 3PH / Output 120V, 208V, 208V 3PH, Extended runtime model Includes: Battery modules ship installed, Bolt down brackets, CD with software, Installation guide, Power modules ship installed, User Manual, Web/SNMP Management Card Features Parallel-capacity capable Parallel-redundant capable Output Output Power Capacity 8000 Watts / 10 kVA Max Configurable Power 8000 Watts / 10 kVA Nominal Output Voltage 120V,208V,208V 3PH Output Voltage Note Configurable for 208 and 220V - 3 Phase Output Voltage Distortion Less than 5% at full load Output Frequency (sync to mains) 57 - 63 Hz for 60 Hz nominal Crest Factor Unlimited Waveform Type Sine wave Output Connections (1) Hard Wire 5-wire (3PH + N + G) (1) Screw Terminals Output Voltage Tolerance +/-1% static and +/- 5% at 100% load step Bypass Built-in Maintenance Bypass,Built-in Static Bypass Input Nominal Input Voltage 208V 3PH Input Frequency 40 - 70 Hz (auto sensing) Input Connections Hard Wire 5-wire (3PH + N + G) Input voltage range for main operations 165 - 240V Other Input Voltages 220 Maximum Input Current 27A Input Breaker Capacity 35A Input Total Harmonic Distortion Less than 5% for full load Type of Input Protection Required 3-pole breaker Batteries & Runtime Battery Type Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof Included Battery Modules 1 Available Battery Slots 1 Typical recharge time 5 hour(s) Replacement Battery SYBT4 RBC™ Quantity 1 Typical Backup Timeat Half Load 18.0 minutes (4000 Watts) Typical Backup Timeat Full Load 5.5 minutes (8000 Watts) Runtime Chart Smart-UPS VT Extended Run Options APC Smart-UPS VT 10kVA 208V with 1 Batt Mod Exp to 2, Int Maint Bypass, Parallel Capable Communications & Management Pre-Installed SmartSlot™ Cards AP9619 Control panel Multi-function LCD status and control console Audible Alarm Audible and visible alarms prioritized by severity Emergency Power Off (EPO) Yes Physical Maximum Height 59.00 inches (1499 mm) Maximum Width 14.00 inches (356 mm) Maximum Depth 32.99 inches (838 mm) Net Weight 671.00 lbs. (305.00 kg) Shipping Weight 739.00 lbs. (335.91 kg) Shipping Height 64.70 inches (1643 mm) Shipping Width 25.60 inches (650 mm) Shipping Depth 41.80 inches (1062 mm) Color Black Environmental Operating Environment 32 - 104 °F (0 - 40 °C) Operating Relative Humidity 0 - 95% Operating Elevation 0-3333 feet (0-999,9 meters) Storage Temperature 5 - 113 °F (-15 - 45 °C) Storage Relative Humidity 0 - 95% Storage Elevation 0-50000 feet (0-15000 meters) Audible noise at 1 meter from surface of unit 54.00 dBA Online Thermal Dissipation 2047.00 BTU/hr Protection Class NEMA 1 Conformance Regulatory Approvals cUL Listed,CE,EN 50091-2,EN/IEC 62040-2,EN/IEC 62040-1-1,FCC Part 15 Class A,ISO 14001,ISO 9001,UL 1778 Standard Warranty 1 year on-site repair or replace with factory authorized Start-UP Protection Class NEMA 1